On Line Current Monitoring and Application of a Residual Method for Eccentricity Fault Detection

A. Metatla
  • Function : Author
S. Benzahioul
  • Function : Author
T. Bahi
  • Function : Author

Abstract

This work concerns the monitoring and diagnosis of faults in induction motors. We develop an approach based on residual analysis of stator currents to detect and diagnose faults eccentricity static, dynamic and mixed in three phase induction motor. To simulate the behavior of motor failure, a model is proposed based on the approach of magnetically coupled coils. The simulation results show the importance of the approach applied for the detection and diagnosis of fault in three phase induction motor.

Dates and versions

hal-01966509 , version 1 (28-12-2018)

Identifiers

Cite

A. Metatla, S. Benzahioul, T. Bahi, D. Lefebvre. On Line Current Monitoring and Application of a Residual Method for Eccentricity Fault Detection. Advances in Electrical and Computer Engineering, 2011, 11 (1), pp.69-72. ⟨10.4316/AECE.2011.01011⟩. ⟨hal-01966509⟩